Event labelOptional labelMethod/DeviceAbbreviationO2A Registry URIDate/TimeLatitudeLongitudeElevationDate/Time endLatitude endLongitude endElevation endComment
MSM83_1-1Profile 1CTD/RosetteCTD-RO2019-05-20T08:09:0038.87617-14.06250-5372calibration stops for Seaguard devices
MSM83_0_Underway-1Ship Weather StationSWEAS2019-05-20T08:09:0038.87600-14.062002019-06-15T11:09:0047.56950-52.69542-35.3
MSM83_2-1Profile 2CTD/RosetteCTD-RO2019-05-20T13:22:0039.14883-14.03100-3641test of acoustic releases 40 m above bottom
MSM83_3-1Profile 3CTD/RosetteCTD-RO2019-05-20T17:11:0039.39150-14.00517-4395calibration stops for MicroCAT, Aquadopp, NKE and RBR devices
MSM83_4-1Profile 4CTD/RosetteCTD-RO2019-05-21T08:09:0041.86883-13.20817-5338calibration stops for Aquadopp devices
MSM83_5-1Profile 5CTD/RosetteCTD-RO2019-05-22T06:52:0046.00050-12.02917-4815test of acoustic releases 30 m above bottom
MSM83_6-1Profile 6CTD/RosetteCTD-RO2019-05-23T02:16:0048.81667-13.42450-4442
MSM83_6-2EB3/3MooringMOOR2019-05-23T06:14:0048.83300-13.43300-4453Recovery, CTD Profile 6
MSM83_7-1Profile 7CTD/RosetteCTD-RO2019-05-23T11:15:0048.99783-12.59267-1534
MSM83_7-2EB1/3MooringMOOR2019-05-23T14:24:0049.00050-12.61900-1534Recovery, CTD Profile 7
MSM83_8-1Profile 8CTD/RosetteCTD-RO2019-05-23T16:44:0049.02617-12.44150-1282
MSM83_9-1Profile 9CTD/RosetteCTD-RO2019-05-23T18:47:0049.07917-12.19450-1019
MSM83_10-1Profile 10CTD/RosetteCTD-RO2019-05-23T20:41:0049.12967-11.94300-858
MSM83_11-1Profile 11CTD/RosetteCTD-RO2019-05-23T22:30:0049.18367-11.69617-797
MSM83_12-1Profile 12CTD/RosetteCTD-RO2019-05-24T00:14:0049.23600-11.44550-470test of radio and Argos beacon
MSM83_13-1Profile 13CTD/RosetteCTD-RO2019-05-24T01:21:0049.26167-11.32167-283
MSM83_14-1Profile 14CTD/RosetteCTD-RO2019-05-24T02:45:0049.20983-11.56967-630
MSM83_15-1Profile 15CTD/RosetteCTD-RO2019-05-24T04:20:0049.15700-11.81817-800
MSM83_16-1Profile 16CTD/RosetteCTD-RO2019-05-24T06:08:0049.10433-12.06717-925
MSM83_17-1Profile 17CTD/RosetteCTD-RO2019-05-24T07:50:0049.05167-12.31783-1138
MSM83_106-1BM-22/10MooringMOOR2019-05-24T12:33:0047.10317-43.22283-3048Deploymen, CTD Profile 103,104
MSM83_18-1EB-3/4MooringMOOR2019-05-24T12:33:0048.83300-13.43383-4454Deploymen, CTD Profile 6
MSM83_18-2Profile 18CTD/RosetteCTD-RO2019-05-24T16:56:0048.83267-13.40733-4320calibration stops for MicroCAT devices, test of radio and flasher beacons
MSM83_19-1Profile 19CTD/RosetteCTD-RO2019-05-24T21:26:0048.89600-13.06317-3630
MSM83_20-1Profile 20CTD/RosetteCTD-RO2019-05-25T00:39:0048.94767-12.81267-2090test of radio and Iridium beacons
MSM83_21-1Profile 21CTD/RosetteCTD-RO2019-05-25T02:37:0048.97367-12.68750-1772
MSM83_22-1Profile 22CTD/RosetteCTD-RO2019-05-25T04:21:0049.00033-12.61783-1543
MSM83_22-2EB-1/4MooringMOOR2019-05-25T07:14:0049.00050-12.61700-1553Deployment, CTD Profile 7
MSM83_23-1Profile 23CTD/RosetteCTD-RO2019-05-25T10:35:0048.92567-12.94983-2620
MSM83_24-1Profile 24CTD/RosetteCTD-RO2019-05-25T13:20:0048.86133-13.23067-3752
MSM83_25-1Profile 25CTD/RosetteCTD-RO2019-05-25T17:44:0048.74967-13.80717-4534
MSM83_26-1Profile 26CTD/RosetteCTD-RO2019-05-26T00:06:0048.67033-14.18150-4544
MSM83_27-1Profile 27CTD/RosetteCTD-RO2019-05-26T04:43:0048.59150-14.55333-4699
MSM83_28-1Profile 28CTD/RosetteCTD-RO2019-05-26T10:15:0048.51867-15.00317-4810
MSM83_28-2BP 32/3Inverted echo sounder equipped with pressure sensorPIES2019-05-26T14:21:0048.51817-15.00167-4784CTD # 28
MSM83_28-1aWMO ID 7900523Argo floatARGOFL2019-05-26T17:37:2448.51760-15.00648CTD # 28
MSM83_29-1Profile 29CTD/RosetteCTD-RO2019-05-26T21:07:0048.47633-16.03100-4838
MSM83_30-1Profile 30CTD/RosetteCTD-RO2019-05-27T03:23:0048.42233-17.03917-4171
MSM83_31-1Profile 31CTD/RosetteCTD-RO2019-05-27T12:07:0048.36833-18.04633-4509
MSM83_32-1Profile 32CTD/RosetteCTD-RO2019-05-27T17:30:0048.34167-18.78100-4351
MSM83_33-1BP 33/2Inverted echo sounder equipped with pressure sensorPIES2019-05-27T23:11:0048.31100-19.52167-4553CTD # 33
MSM83_33-3Profile 33CTD/RosetteCTD-RO2019-05-28T07:33:0048.31200-19.52067-4569
MSM83_34-1Profile 34CTD/RosetteCTD-RO2019-05-28T12:15:0048.26267-20.49867-4180
MSM83_35-1Profile 35CTD/RosetteCTD-RO2019-05-28T18:14:0048.21250-21.47567-4453
MSM83_36-1Profile 36CTD/RosetteCTD-RO2019-05-29T00:24:0048.16217-22.45283-4253
MSM83_37-1BP 34/2Inverted echo sounder equipped with pressure sensorPIES2019-05-29T08:00:0048.11150-23.41933-4484CTD # 38
MSM83_38-1Profile 37CTD/RosetteCTD-RO2019-05-29T12:48:0048.08583-23.91483-4089
MSM83_39-1Profile 38CTD/RosetteCTD-RO2019-05-29T17:07:0048.11300-23.41767-4503
MSM83_39-2BP 34/2Inverted echo sounder equipped with pressure sensorPIES2019-05-29T21:06:0048.11150-23.41933-4484CTD # 38
MSM83_39-3BP 34/3Inverted echo sounder equipped with pressure sensorPIES2019-05-29T23:08:0048.11150-23.41917-4484CTD # 38
MSM83_40-1Profile 39CTD/RosetteCTD-RO2019-05-30T07:46:0048.02783-25.12450-3885
MSM83_41-1Profile 40CTD/RosetteCTD-RO2019-05-30T14:56:0047.95867-26.33383-3015
MSM83_41-1aWMO ID 7900524Argo floatARGOFL2019-05-30T16:40:3147.95830-26.33882CTD # 40
MSM83_42-1Profile 41CTD/RosetteCTD-RO2019-05-30T22:33:0047.88900-27.54333-3443
MSM83_43-1Profile 42CTD/RosetteCTD-RO2019-05-31T06:04:0047.81967-28.75317-2999profile aborted during downcast @2730 dbar due to electronic failure
MSM83_44-1Profile 43CTD/RosetteCTD-RO2019-05-31T12:54:0047.75050-29.96250-3487
MSM83_45-1Profile 44CTD/RosetteCTD-RO2019-05-31T19:21:0047.66333-31.14350-4095
MSM83_45-2BP 12/6Inverted echo sounder equipped with pressure sensorPIES2019-05-31T22:06:0047.66317-31.14433-4094CTD # 44
MSM83_46-1Profile 45CTD/RosetteCTD-RO2019-06-02T04:00:0051.70783-35.90667-3448
MSM83_47-1Profile 46CTD/RosetteCTD-RO2019-06-02T08:35:0052.11317-36.38550-3352
MSM83_48-1Profile 47CTD/RosetteCTD-RO2019-06-02T12:52:0052.31417-36.62817-3714profile aborted during downcast @300 dbar due to electronic failure
MSM83_49-1Profile 48CTD/RosetteCTD-RO2019-06-02T15:56:0052.50117-36.86067-3429calibration stops for Seaguard devices
MSM83_49-2BP 15/4Inverted echo sounder equipped with pressure sensorPIES2019-06-02T19:06:0052.50883-36.86550-3387CTD # 48
MSM83_50-1Profile 49CTD/RosetteCTD-RO2019-06-03T06:57:0051.30233-35.42600-3719
MSM83_51-1Profile 50CTD/RosetteCTD-RO2019-06-03T11:54:0050.89500-34.94383-3565test of acoustic releases 30 m above bottom
MSM83_52-1Profile 51CTD/RosetteCTD-RO2019-06-03T16:53:0050.49033-34.46733-4060calibration stops for MicroCAT, Aquadopp and NKE devices
MSM83_53-1Profile 52CTD/RosetteCTD-RO2019-06-03T22:25:0050.08383-33.98517-4258
MSM83_54-1Profile 53CTD/RosetteCTD-RO2019-06-04T03:15:0049.67833-33.50683-4023
MSM83_55-1Profile 54CTD/RosetteCTD-RO2019-06-04T08:18:0049.27350-33.02683-3819
MSM83_56-1Profile 55CTD/RosetteCTD-RO2019-06-04T13:35:0048.86650-32.54500-3820
MSM83_57-1Profile 56CTD/RosetteCTD-RO2019-06-04T18:37:0048.46200-32.06583-4205
MSM83_58-1Profile 57CTD/RosetteCTD-RO2019-06-04T23:49:0048.05567-31.58383-3928
MSM83_58-1aWMO ID 7900525Argo floatARGOFL2019-06-05T02:10:0048.05342-31.58477CTD # 57
MSM83_59-1Profile 58CTD/RosetteCTD-RO2019-06-05T04:30:0047.62433-31.62450-3748
MSM83_60-1Profile 59CTD/RosetteCTD-RO2019-06-05T10:31:0047.57467-32.57683-3955
MSM83_61-1Profile 60CTD/RosetteCTD-RO2019-06-05T16:29:0047.51383-33.53533-4090
MSM83_62-1Profile 61CTD/RosetteCTD-RO2019-06-05T22:07:0047.45450-34.49117-4403
MSM83_62-1aWMO ID 7900526Argo floatARGOFL2019-06-06T00:43:0047.45513-34.49397CTD # 61
MSM83_63-1Profile 62CTD/RosetteCTD-RO2019-06-06T04:04:0047.39433-35.44867-4309
MSM83_64-1Profile 63CTD/RosetteCTD-RO2019-06-06T10:15:0047.33400-36.40500-4235
MSM83_65-1Profile 64CTD/RosetteCTD-RO2019-06-06T15:56:0047.29950-37.34917-4547
MSM83_65-2BP 30/2Inverted echo sounder equipped with pressure sensorPIES2019-06-06T19:24:0047.30100-37.36167-4539CTD # 64
MSM83_66-1Profile 65CTD/RosetteCTD-RO2019-06-07T00:50:0047.25117-37.94350-4588
MSM83_66-1aWMO ID 7900529Argo floatARGOFL2019-06-07T03:33:0047.25128-37.94583CTD # 65
MSM83_67-1Profile 66CTD/RosetteCTD-RO2019-06-07T05:40:0047.20817-38.51783-4614
MSM83_68-1Profile 67CTD/RosetteCTD-RO2019-06-07T10:09:0047.17117-39.02000-4588
MSM83_69-1BP 28/4Inverted echo sounder equipped with pressure sensorPIES2019-06-07T14:52:0047.17017-39.47833-4605CTD # 68
MSM83_69-2Profile 68CTD/RosetteCTD-RO2019-06-07T18:11:0047.17767-39.47450-4580
MSM83_70-1Profile 69CTD/RosetteCTD-RO2019-06-07T23:27:0047.10983-40.18817-4565
MSM83_73-2BP 31/3Inverted echo sounder equipped with pressure sensorPIES2019-06-08T00:00:0047.08617-42.01283-4246CTD # 72
MSM83_71-1Profile 70CTD/RosetteCTD-RO2019-06-08T04:23:0047.10950-40.87750-4740
MSM83_71-2BP 27/4Inverted echo sounder equipped with pressure sensorPIES2019-06-08T08:07:0047.10183-40.88400-4499CTD # 70
MSM83_71-1aWMO ID 7900527Argo floatARGOFL2019-06-08T11:08:0047.10168-40.88400CTD # 70
MSM83_72-1Profile 71CTD/RosetteCTD-RO2019-06-08T13:13:0047.10533-41.44983-4341
MSM83_73-1Profile 72CTD/RosetteCTD-RO2019-06-08T18:30:0047.09817-41.99800-4236
MSM83_74-1Profile 73CTD/RosetteCTD-RO2019-06-08T23:56:0047.10067-42.22367-4074
MSM83_74-2BM-24/6MooringMOOR2019-06-09T08:02:0047.10350-42.27450-4008Recovery, CTD Profile 73
MSM83_75-1BM-22/9MooringMOOR2019-06-09T14:15:0047.10317-43.22283-3048Recovery, CTD Profile 74
MSM83_75-2Profile 74CTD/RosetteCTD-RO2019-06-09T16:48:0047.10250-43.21833-3059
MSM83_76-1BP 31/3Inverted echo sounder equipped with pressure sensorPIES2019-06-09T23:25:0047.08617-42.01283-4246CTD # 72
MSM83_76-2BP 31/4Inverted echo sounder equipped with pressure sensorPIES2019-06-10T01:30:0047.09833-42.01700-4222CTD # 72
MSM83_77-1Profile 75CTD/RosetteCTD-RO2019-06-10T04:13:0047.10367-42.27417-4013
MSM83_78-1Profile 76CTD/RosetteCTD-RO2019-06-10T08:01:0047.10067-42.59017-3680
MSM83_78-1aWMO ID 7900528Argo floatARGOFL2019-06-10T10:16:0047.08845-42.58923CTD # 76
MSM83_79-1Profile 77CTD/RosetteCTD-RO2019-06-10T11:41:0047.10033-42.89333-3467test of radio, flasher, and Iridium beacons
MSM83_80-1Profile 78CTD/RosetteCTD-RO2019-06-10T14:50:0047.10200-43.11867-3514
MSM83_81-1Profile 79CTD/RosetteCTD-RO2019-06-10T17:38:0047.10333-43.22267-3049
MSM83_82-1Profile 80CTD/RosetteCTD-RO2019-06-10T19:57:0047.10100-43.29633-2677
MSM83_83-1Profile 81CTD/RosetteCTD-RO2019-06-10T21:57:0047.09917-43.33233-1960
MSM83_84-1Profile 82CTD/RosetteCTD-RO2019-06-10T23:42:0047.10067-43.42033-1292
MSM83_85-1Profile 83CTD/RosetteCTD-RO2019-06-11T01:42:0047.09983-43.63917-775
MSM83_86-1Profile 84CTD/RosetteCTD-RO2019-06-11T03:09:0047.09983-43.79050-595
MSM83_87-1Profile 85CTD/RosetteCTD-RO2019-06-11T05:00:0047.10100-44.04167-364
MSM83_88-1Profile 86CTD/RosetteCTD-RO2019-06-11T06:55:0047.09317-44.29800-252
MSM83_89-1Profile 87CTD/RosetteCTD-RO2019-06-11T08:26:0047.10033-44.49950-165
MSM83_90-1BM-25/6MooringMOOR2019-06-11T19:32:0047.11850-47.10633-1003Recovery, CTD Profile 88
MSM83_90-2Profile 88CTD/RosetteCTD-RO2019-06-11T20:22:0047.11817-47.10617-1013
MSM83_91-1Profile 89CTD/RosetteCTD-RO2019-06-11T22:18:0047.09367-47.38017-243
MSM83_92-1Profile 90CTD/RosetteCTD-RO2019-06-11T22:56:0047.09633-47.32267-313
MSM83_93-1Profile 91CTD/RosetteCTD-RO2019-06-11T23:41:0047.09850-47.26350-483
MSM83_94-1Profile 92CTD/RosetteCTD-RO2019-06-12T00:26:0047.10000-47.20800-739
MSM83_95-1Profile 93CTD/RosetteCTD-RO2019-06-12T01:21:0047.09883-47.15467-890
MSM83_96-1Profile 94CTD/RosetteCTD-RO2019-06-12T02:26:0047.09833-47.09733-1034
MSM83_97-1Profile 95CTD/RosetteCTD-RO2019-06-12T03:39:0047.10100-47.00883-1134
MSM83_98-1Profile 96CTD/RosetteCTD-RO2019-06-12T05:12:0047.10017-46.85400-1178
MSM83_99-1Profile 97CTD/RosetteCTD-RO2019-06-12T06:42:0047.10000-46.70733-1148
MSM83_100-1Profile 98CTD/RosetteCTD-RO2019-06-12T07:47:0047.10083-46.66583-1107
MSM83_101-1Profile 99CTD/RosetteCTD-RO2019-06-12T08:56:0047.10133-46.61017-820
MSM83_102-1Profile 100CTD/RosetteCTD-RO2019-06-12T09:52:0047.10100-46.55333-502
MSM83_103-1Profile 101CTD/RosetteCTD-RO2019-06-12T10:56:0047.10217-46.40283-363
MSM83_104-1Profile 102CTD/RosetteCTD-RO2019-06-12T12:20:0047.10117-46.13917-336
MSM83_105-1Profile 103CTD/RosetteCTD-RO2019-06-12T22:07:0047.10317-43.22200-3032calibration stops for MicroCAT and Aquadopp devices
MSM83_105-2Profile 104CTD/RosetteCTD-RO2019-06-13T01:11:0047.09933-43.21267-3052calibration stops for MicroCAT and Aquadopp devices
MSM83_33-2BP 33/3Inverted echo sounder equipped with pressure sensorPIES2019-06-28T03:42:0048.31100-19.52150-4553CTD # 33