Event labelOptional labelMethod/DeviceAbbreviationO2A Registry URIDate/TimeLatitudeLongitudeElevationDate/Time endLatitude endLongitude endElevation endComment
M87/3b-trackUnderway cruise track measurementsCT2012-06-12T00:00:0054.1604012.100602012-06-25T00:00:0054.1604012.10060Rostock - Rostock
M87/3b_1-1TF0213MultibeamMB2012-06-12T08:00:0054.2455011.90950-13.72012-06-13T06:40:0055.2505015.98317-86.1Multibeam and Parasound
M87/3b_1-2TF0213CTD/RosetteCTD-RO2012-06-13T06:51:0055.2498315.98317-86
M87/3b_1-3TF0213Micro structure probeMSS2012-06-13T07:24:0055.2501715.98467-86
M87/3b_1-4TF0213Micro structure probeMSS2012-06-13T07:33:0055.2515015.98900-85.9
M87/3b_2TF0250CTD/RosetteCTD-RO2012-06-13T18:18:0056.0830019.16700-121.3
M87/3b_3TF0263CTD/RosetteCTD-RO2012-06-13T20:58:0056.3466719.37700-130.6
M87/3b_4TF260CTD/RosetteCTD-RO2012-06-13T23:29:0056.6331719.58233-141.2
M87/3b_5-1GB1CTD/RosetteCTD-RO2012-06-14T01:52:0056.9163319.33200-170
M87/3b_5-2GB1MultiCorerMUC2012-06-14T02:31:0056.9163319.33217-169.9
M87/3b_5-3GB1MultiCorerMUC2012-06-14T03:18:0056.9163319.33200-170.2
M87/3b_5-4GB1Freeze corerFRC2012-06-14T03:58:0056.9163319.33183-170.4
M87/3b_6TF272CTD/RosetteCTD-RO2012-06-14T06:06:0057.0718319.82950-209.6
M87/3b_7-1TF0271CTD/RosetteCTD-RO2012-06-14T08:15:0057.3198320.04983-238.4with Automatic Fixation in situ Samplers (AFIS)
M87/3b_7-2TF0271CTD/RosetteCTD-RO2012-06-14T09:18:0057.3198320.05000-239.9
M87/3b_7-3TF0271Micro structure probeMSS2012-06-14T10:32:0057.3196720.04933-239.2
M87/3b_7-4TF0271Micro structure probeMSS2012-06-14T10:47:0057.3173320.04117-238
M87/3b_7-5TF0271Micro structure probeMSS2012-06-14T12:00:0057.3028319.99850-234.4
M87/3b_7-6TF0271CTD/RosetteCTD-RO2012-06-14T13:03:0057.3201720.05033-477.6with Automatic Fixation in situ Samplers (AFIS)
M87/3b_7-7TF0271Scan fishSCF2012-06-14T13:57:0057.3198320.05050-265.32012-06-14T19:03:0057.0778320.76500-68.7
M87/3b_8-1go0001CTD/RosetteCTD-RO2012-06-14T20:31:0057.0271720.35233-109.7
M87/3b_8-2go0001Mooring (short time)MOORST2012-06-14T21:18:0057.0256720.35050-109.2
M87/3b_8-3go0001Mooring (short time)MOORST2012-06-14T21:54:0057.0235020.35033-107.7
M87/3b_8-4go0001CTD/RosetteCTD-RO2012-06-14T22:26:0057.0271720.35283-109.3with Automatic Fixation in situ Samplers (AFIS)
M87/3b_8-5go0001MultiCorerMUC2012-06-14T23:48:0057.0270020.35217-109.5
M87/3b_8-6Micro structure probeMSS2012-06-15T00:20:0057.0268320.35317-108.8
M87/3b_8-7Micro structure probeMSS2012-06-15T04:16:0056.9801720.49867-34.1
M87/3b_9go0001CTD/RosetteCTD-RO2012-06-15T09:02:0057.0273320.35217-109.7with Automatic Fixation in situ Samplers (AFIS)
M87/3b_10-1GT1-2CTD/RosetteCTD-RO2012-06-15T10:33:0057.0118320.40000-89.4with Automatic Fixation in situ Samplers (AFIS)
M87/3b_10-2GT1-2MultiCorerMUC2012-06-15T11:15:0057.0118320.39983-89.7
M87/3b_10-3GT1-2Micro structure probeMSS2012-06-15T11:58:0057.0121720.39900-89.7
M87/3b_11-1GT1-3CTD/RosetteCTD-RO2012-06-15T13:01:0056.9923320.46033-79.7with Automatic Fixation in situ Samplers (AFIS)
M87/3b_11-2GT1-3MultiCorerMUC2012-06-15T13:37:0056.9925020.46000-79.9
M87/3b_11-3GT1-3Micro structure probeMSS2012-06-15T13:56:0056.9925020.45983-80.1
M87/3b_12-4GT1-4CTD/RosetteCTD-RO2012-06-15T16:33:0056.9878320.47433-67.8with Automatic Fixation in situ Samplers (AFIS)
M87/3b_12-5GT1-4MultiCorerMUC2012-06-15T17:13:0056.9876720.47433-68.4
M87/3b_12-6GT1-4MultibeamMB2012-06-15T17:55:0056.9955020.46433-78.52012-06-15T19:58:0057.3198320.04867-237.8Multibeam and Parasound
M87/3b_13-1TF0271CTD/RosetteCTD-RO2012-06-15T20:01:0057.3200020.04850-238
M87/3b_13-2Micro structure probeMSS2012-06-15T21:57:0057.3198320.04817-237.9
M87/3b_13-3Micro structure probeMSS2012-06-16T04:15:0057.3263320.08400-241
M87/3b_14-1TF0271CTD/RosetteCTD-RO2012-06-16T06:35:0057.3200020.04950-238
M87/3b_14-2TF0271CTD/RosetteCTD-RO2012-06-16T07:24:0057.3201720.05000-238.1with Automatic Fixation in situ Samplers (AFIS)
M87/3b_14-3MultibeamMB2012-06-16T08:37:0057.3186720.05417-238.42012-06-16T11:56:0056.7486719.65967-138.2Multibeam and Parasound
M87/3b_15-1TF0260CTD/RosetteCTD-RO2012-06-16T12:51:0056.6336719.58300-141.1with Automatic Fixation in situ Samplers (AFIS)
M87/3b_15-2TF0260Micro structure probeMSS2012-06-16T14:13:0056.6330019.58317-141.5
M87/3b_15-3TF0260Micro structure probeMSS2012-06-16T15:41:0056.6506719.59500-140.4
M87/3b_15-4TF0260CTD/RosetteCTD-RO2012-06-16T17:01:0056.6335019.58350-141.5with Automatic Fixation in situ Samplers (AFIS)
M87/3b_15-5TF0260Micro structure probeMSS2012-06-16T17:58:0056.6493319.59400-140.5
M87/3b_15-6TF0260CTD/RosetteCTD-RO2012-06-16T18:57:0056.6335019.58333-141.7with Automatic Fixation in situ Samplers (AFIS)
M87/3b_15-7TF0260Micro structure probeMSS2012-06-16T19:42:0056.6316719.58250-141.6
M87/3b_15-8TF0260Micro structure probeMSS2012-06-16T20:40:0056.6176719.57200-141.3
M87/3b_15-9TF0260CTD/RosetteCTD-RO2012-06-16T21:16:0056.6333319.58317-141.4with Automatic Fixation in situ Samplers (AFIS)
M87/3b_15-10TF0260Micro structure probeMSS2012-06-16T22:11:0056.6338319.58367-141.4
M87/3b_15-11MultibeamMB2012-06-17T05:20:0056.8861720.07500-157.42012-06-17T06:20:0057.0271720.35050-110.2Multibeam and Parasound
M87/3b_15-12MooringMOOR2012-06-17T07:20:0057.0245020.35267-107.8ADCP on deck
M87/3b_15-13MultibeamMB2012-06-17T07:34:0057.0278320.34933-121.72012-06-17T12:21:0057.9498320.60067-92.1Multibeam and Parasound
M87/3b_15-14MultibeamMB2012-06-17T17:53:0058.3406718.86800-158.92012-06-17T20:02:0058.5835018.23350-436.8
M87/3b_16-1TF284CTD/RosetteCTD-RO2012-06-17T20:07:0058.5835018.23350-436.8with Automatic Fixation in situ Samplers (AFIS)
M87/3b_16-2TF284MultibeamMB2012-06-17T21:30:0058.5833318.23350-436.82012-06-18T03:54:0058.7333318.35967-100.6Multibeam and Parasound
M87/3b_17-1LT1CTD/RosetteCTD-RO2012-06-18T03:57:0058.7331718.35950-101with Automatic Fixation in situ Samplers (AFIS)
M87/3b_17-2LT1MultiCorerMUC2012-06-18T04:34:0058.7335018.36000-99.2
M87/3b_17-3LT1MultiCorerMUC2012-06-18T05:04:0058.7335018.36017-99.2
M87/3b_17-4LT1MultiCorerMUC2012-06-18T05:30:0058.7335018.36033-99.1
M87/3b_17-5LT1MultiCorerMUC2012-06-18T05:47:0058.7335018.36000-100.5
M87/3b_17-6LT1Freeze corerFRC2012-06-18T06:09:0058.7335018.35983-100.3
M87/3b_17-7LT1Freeze corerFRC2012-06-18T06:30:0058.7335018.35967-101
M87/3b_17-8MultibeamMB2012-06-18T07:00:0058.7260018.35283-93.92012-06-18T08:05:0058.5836718.23367-436.3Multibeam and Parasound
M87/3b_18-1TF284CTD/RosetteCTD-RO2012-06-18T08:07:0058.5833318.23350-436.4with Automatic Fixation in situ Samplers (AFIS)
M87/3b_18-2TF284CTD/RosetteCTD-RO2012-06-18T09:57:0058.5833318.23350-420.9
M87/3b_18-3MultibeamMB2012-06-18T10:58:0058.5945018.24583-353.72012-06-18T12:27:0058.8348318.46667-78.7Multibeam and Parasound
M87/3b_18-4Scan fishSCF2012-06-18T12:42:0058.8385018.46700-111.4
M87/3b_18-5Scan fishSCF2012-06-18T19:17:0058.1846718.46650-39.5
M87/3b_19Lars-LBCTD/RosetteCTD-RO2012-06-18T20:19:0058.3380018.46633-112.6with Automatic Fixation in situ Samplers (AFIS)
M87/3b_20-1MSS-LBCTD/RosetteCTD-RO2012-06-18T21:36:0058.3873318.46633-128.7with Automatic Fixation in situ Samplers (AFIS)
M87/3b_20-2Micro structure probeMSS2012-06-18T22:13:0058.3866718.46617-127.7
M87/3b_20-3Micro structure probeMSS2012-06-19T02:37:0058.2821718.46700-61.1
M87/3b_20-4Micro structure probeMSS2012-06-19T04:08:0058.3126718.46600-95.8
M87/3b_20-5MooringMOOR2012-06-19T06:26:0058.3196718.46717-106ADCP
M87/3b_20-6MooringMOOR2012-06-19T07:00:0058.3178318.46533-103.3slipped
M87/3b_21X_0021CTD/RosetteCTD-RO2012-06-19T07:32:0058.3131718.46633-97with Automatic Fixation in situ Samplers (AFIS)
M87/3b_22X_0022CTD/RosetteCTD-RO2012-06-19T08:12:0058.3066718.46633-77.7with Automatic Fixation in situ Samplers (AFIS)
M87/3b_23-1X_0023MultiCorerMUC2012-06-19T08:42:0058.3065018.46633-77.6
M87/3b_23-2X_0023CTD/RosetteCTD-RO2012-06-19T09:45:0058.3133318.46650-97.7with Automatic Fixation in situ Samplers (AFIS)
M87/3b_23-3Micro structure probeMSS2012-06-19T10:37:0058.3141718.46750-99.6
M87/3b_23-4Micro structure probeMSS2012-06-19T11:33:0058.3376718.46633-491.1
M87/3b_24-1LT1-2CTD/RosetteCTD-RO2012-06-19T11:57:0058.3200018.46750-106.2with Automatic Fixation in situ Samplers (AFIS)
M87/3b_24-2Micro structure probeMSS2012-06-19T12:44:0058.3216718.46700-108.2
M87/3b_24-3Micro structure probeMSS2012-06-19T13:33:0058.3336718.44800-111.7
M87/3b_25-1LT1-3CTD/RosetteCTD-RO2012-06-19T13:51:0058.3403318.46767-112.2with Automatic Fixation in situ Samplers (AFIS)
M87/3b_25-2Micro structure probeMSS2012-06-19T14:35:0058.3401718.46683-113.1
M87/3b_25-3Micro structure probeMSS2012-06-19T15:20:0058.3416718.43200-119.1
M87/3b_26-1LT1-4CTD/RosetteCTD-RO2012-06-19T15:37:0058.3606718.46733-116.3with Automatic Fixation in situ Samplers (AFIS)
M87/3b_26-2Micro structure probeMSS2012-06-19T16:26:0058.3626718.46667-117.5
M87/3b_26-3Micro structure probeMSS2012-06-19T17:06:0058.3821718.46700-125.6
M87/3b_27-1LT1-5CTD/RosetteCTD-RO2012-06-19T17:15:0058.3833318.46717-125.9with Automatic Fixation in situ Samplers (AFIS)
M87/3b_27-2MultibeamMB2012-06-19T18:20:0058.3831718.46617-125.22012-06-19T19:45:0058.5821718.23333-435.2Multibeam and Parasound
M87/3b_28-1TF0284CTD/RosetteCTD-RO2012-06-19T19:53:0058.5831718.23317-437.8
M87/3b_28-2TF0284CTD/RosetteCTD-RO2012-06-19T20:57:0058.5833318.23317-437.4with Automatic Fixation in situ Samplers (AFIS)
M87/3b_28-3TF0284MultibeamMB2012-06-19T21:36:0058.5740018.24533-289.92012-06-20T06:08:0058.6398318.53900-207Multibeam and Parasound
M87/3b_28-4MultiCorerMUC2012-06-20T06:39:0058.6116718.45633-160
M87/3b_28-5Freeze corerFRC2012-06-20T07:08:0058.6116718.45633-160
M87/3b_29-1LT5CTD/RosetteCTD-RO2012-06-20T07:51:0058.6216718.44800-180.2with Automatic Fixation in situ Samplers (AFIS)
M87/3b_29-2LT5MultiCorerMUC2012-06-20T08:47:0058.6216718.44800-180.3
M87/3b_29-3LT5MultiCorerMUC2012-06-20T09:18:0058.6216718.44783-180.4
M87/3b_29-4LT5Freeze corerFRC2012-06-20T09:44:0058.6216718.44783-180.6
M87/3b_29-5MultibeamMB2012-06-20T10:15:0058.6218318.44750-206.52012-06-20T11:01:0058.5840018.23233-438.6
M87/3b_30-1TF0284CTD/RosetteCTD-RO2012-06-20T11:03:0058.5836718.23183-438.8
M87/3b_30-2TF0284CTD/RosetteCTD-RO2012-06-20T11:54:0058.5833318.23317-396with Automatic Fixation in situ Samplers (AFIS)
M87/3b_30-3TF0284CTD/RosetteCTD-RO2012-06-20T13:09:0058.5833318.23333-436.8with Automatic Fixation in situ Samplers (AFIS)
M87/3b_30-4TF0284Micro structure probeMSS2012-06-20T13:39:0058.5831718.23283-437
M87/3b_30-5TF0284Micro structure probeMSS2012-06-20T14:34:0058.5748318.22167-308.9
M87/3b_30-6TF0284CTD/RosetteCTD-RO2012-06-20T16:07:0058.5833318.23333-437.3with Automatic Fixation in situ Samplers (AFIS)
M87/3b_30-7MultibeamMB2012-06-20T16:48:0058.5835018.23967-412.72012-06-20T17:30:0058.6470018.42817-445Multibeam and Parasound
M87/3b_31-1LT4CTD/RosetteCTD-RO2012-06-20T17:43:0058.6470018.42833-285.5
M87/3b_31-2LT4MultiCorerMUC2012-06-20T19:00:0058.6470018.42833
M87/3b_31-3LT4MultiCorerMUC2012-06-20T19:36:0058.6470018.42833-228.4
M87/3b_31-4LT4Freeze corerFRC2012-06-20T20:10:0058.6468318.42817-228.8
M87/3b_32-1LT3MultiCorerMUC2012-06-20T22:02:0058.6570018.42067-281.7
M87/3b_32-2LT3Freeze corerFRC2012-06-20T22:38:0058.6570018.42083-281.8
M87/3b_32-3Micro structure probeMSS2012-06-21T00:53:0058.3865018.46650-127.8
M87/3b_32-4Micro structure probeMSS2012-06-21T05:13:0058.2901718.46667-62.6
M87/3b_33-1LT2-5CTD/RosetteCTD-RO2012-06-21T08:08:0058.3801718.46667-124.5with Automatic Fixation in situ Samplers (AFIS)
M87/3b_33-2Micro structure probeMSS2012-06-21T09:03:0058.3800018.46633-124.2
M87/3b_33-3Micro structure probeMSS2012-06-21T09:58:0058.3726718.46667-120.2
M87/3b_34-1LT2-4CTD/RosetteCTD-RO2012-06-21T10:24:0058.3503318.46667-113.8with Automatic Fixation in situ Samplers (AFIS)
M87/3b_34-2Micro structure probeMSS2012-06-21T11:04:0058.3498318.46633-113.7
M87/3b_34-3Micro structure probeMSS2012-06-21T11:52:0058.3421718.46667-113.2
M87/3b_35-1LT1-3CTD/RosetteCTD-RO2012-06-21T12:01:0058.3398318.46667-113.1with Automatic Fixation in situ Samplers (AFIS)
M87/3b_35-2LT1-3Micro structure probeMSS2012-06-21T12:37:0058.3398318.46667-113.1
M87/3b_35-3Micro structure probeMSS2012-06-21T13:28:0058.3318318.46667-111.8
M87/3b_36-1LT2-2CTD/RosetteCTD-RO2012-06-21T13:36:0058.3301718.46667-112.3with Automatic Fixation in situ Samplers (AFIS)
M87/3b_36-2Micro structure probeMSS2012-06-21T14:06:0058.3300018.46667-112.3
M87/3b_36-3Micro structure probeMSS2012-06-21T14:47:0058.3180018.45950-100.1
M87/3b_37-1LT1-1CTD/RosetteCTD-RO2012-06-21T14:56:0058.3131718.46650-98.1with Automatic Fixation in situ Samplers (AFIS)
M87/3b_37-2MultibeamMB2012-06-21T15:26:0058.3155018.46700-101.12012-06-21T17:25:0058.6721718.40850-345.7Multibeam and Parasound
M87/3b_38-1LT2CTD/RosetteCTD-RO2012-06-21T17:25:0058.6721718.40850-345.7with Automatic Fixation in situ Samplers (AFIS)
M87/3b_38-2LT2MultiCorerMUC2012-06-21T18:30:0058.6715018.40900-344.8
M87/3b_38-3LT2MultiCorerMUC2012-06-21T19:05:0058.6715018.40900-345.3
M87/3b_38-4LT2Freeze corerFRC2012-06-21T19:43:0058.6715018.40917-345.2
M87/3b_38-5LT2MultibeamMB2012-06-21T20:36:0058.6715018.41017-3452012-06-21T21:30:0058.5833318.23267-437.5Multibeam and Parasound
M87/3b_38-6Micro structure probeMSS2012-06-21T21:44:0058.5833318.23333-436.2
M87/3b_38-7Micro structure probeMSS2012-06-21T23:20:0058.5925018.25733-214.1
M87/3b_38-8Micro structure probeMSS2012-06-21T23:45:0058.5793318.20183-136.9
M87/3b_38-9Micro structure probeMSS2012-06-22T02:21:0058.5863318.25533-206.1
M87/3b_38-10Micro structure probeMSS2012-06-22T02:48:0058.5800018.21883-225.9
M87/3b_38-11Micro structure probeMSS2012-06-22T05:19:0058.5888318.25567-211.4
M87/3b_38-12Micro structure probeMSS2012-06-22T06:00:0058.5801718.22017-290.3
M87/3b_38-13Micro structure probeMSS2012-06-22T06:55:0058.5831718.23283-436.6
M87/3b_39-1TF0284CTD/RosetteCTD-RO2012-06-22T07:08:0058.5833318.23333-436.7
M87/3b_39-2TF0284CTD/RosetteCTD-RO2012-06-22T10:44:0058.5833318.23333-437.2
M87/3b_39-3TF0284CTD/RosetteCTD-RO2012-06-22T11:29:0058.5833318.23333-436.9with Automatic Fixation in situ Samplers (AFIS)
M87/3b_39-4MultibeamMB2012-06-22T12:13:0058.5888318.23600-440.32012-06-23T08:02:0058.3145018.47050-101
M87/3b_39-5MooringMOOR2012-06-23T08:03:0058.3145018.47033-101.1Hydrophone in water
M87/3b_39-6MooringMOOR2012-06-23T09:19:0058.3166718.46967-103.2ADCP
M87/3b_40-1X_0040CTD/RosetteCTD-RO2012-06-23T09:55:0058.3181718.46683-103.9with Automatic Fixation in situ Samplers (AFIS)
M87/3b_40-2Micro structure probeMSS2012-06-23T10:59:0058.2415018.46733-55.7
M87/3b_40-3Micro structure probeMSS2012-06-23T16:18:0058.3966718.46650-130.5Multibeam and Parasound
M87/3b_40-4MultibeamMB2012-06-23T16:33:0058.3841618.43283-132.72012-06-23T18:01:0058.1773318.03366-132.2