Event labelOptional labelMethod/DeviceAbbreviationO2A Registry URIDate/TimeLatitudeLongitudeElevationDate/Time endLatitude endLongitude endElevation endComment
M135-trackUnderway cruise track measurementsCT2017-03-01T00:00:00-33.03000-71.650002017-04-08T00:00:00-12.06000-77.15000
M135_179-1CTD 001CTD/RosetteCTD-RO2017-03-02T12:15:00-31.03000-72.10500-2697
M135_180-1CTD 002CTD/RosetteCTD-RO2017-03-02T20:05:00-30.00133-71.74850-1876
M135_181-1CTD 003CTD/RosetteCTD-RO2017-03-03T03:16:00-28.83167-71.66500-2245
M135_182-1CTD 004CTD/RosetteCTD-RO2017-03-03T09:12:00-28.00017-71.33283-1679
M135_183-1CTD 005CTD/RosetteCTD-RO2017-03-03T16:14:00-26.99883-71.08417-1433
M135_184-1CTD/Rosette, ultra cleanCTD-UC2017-03-03T22:40:00-25.99967-71.00017-19752017-03-03T23:09:00-25.99900-71.00100-1980
M135_184-2CTD 006CTD/RosetteCTD-RO2017-03-04T00:00:00-25.99867-71.00150-1981
M135_185-1CTD/Rosette, ultra cleanCTD-UC2017-03-04T06:53:00-24.99817-70.83383-1657
M135_185-2CTD 007CTD/RosetteCTD-RO2017-03-04T07:45:00-24.99933-70.83233-1655
M135_186-1CTD/Rosette, ultra cleanCTD-UC2017-03-04T14:00:00-24.00083-70.75150-22842017-03-04T14:25:00-24.00000-70.75217-2292.7
M135_186-2CTD 008CTD/RosetteCTD-RO2017-03-04T15:16:00-23.99950-70.75283-2293
M135_187-1CTD/Rosette, ultra cleanCTD-UC2017-03-04T21:47:00-22.99900-70.64883-10562017-03-04T22:13:00-22.99883-70.64900-1059.9
M135_187-2CTD 009CTD/RosetteCTD-RO2017-03-04T22:39:00-22.99883-70.64900-1068
M135_188-1CTD/Rosette, ultra cleanCTD-UC2017-03-04T23:42:00-22.99950-70.74933-20572017-03-05T00:24:00-22.99933-70.74967-2060
M135_188-2CTD 010CTD/RosetteCTD-RO2017-03-05T01:12:00-22.99933-70.74967-2060
M135_189-1CTD 011CTD/RosetteCTD-RO2017-03-05T04:05:00-22.99900-71.00050-4614
M135_190-1CTD 012CTD/RosetteCTD-RO2017-03-05T08:14:00-22.99867-71.50550-6387
M135_191-1CTD/Rosette, ultra cleanCTD-UC2017-03-05T11:40:00-23.00017-72.00033-44312017-03-05T12:22:00-23.00017-72.00050-4432.5
M135_191-2CTD 013CTD/RosetteCTD-RO2017-03-05T13:06:00-23.00017-72.00067-4432
M135_192-1CTD/Rosette, ultra cleanCTD-UC2017-03-05T19:35:00-23.00000-73.00067-35342017-03-05T20:17:00-23.00000-73.00150-3533.8
M135_192-2CTD 014CTD/RosetteCTD-RO2017-03-05T21:05:00-23.00100-73.00000-3531
M135_193-1CTD 015CTD/RosetteCTD-RO2017-03-06T03:31:00-23.00050-73.99883-4077
M135_193-2CTD/Rosette, ultra cleanCTD-UC2017-03-06T04:08:00-23.00017-73.99967-4079
M135_193-3CTD 016CTD/RosetteCTD-RO2017-03-06T05:09:00-23.00000-74.00017-4076
M135_194-1CTD 017CTD/RosetteCTD-RO2017-03-06T12:09:00-21.99967-74.00017-4630
M135_195-1CTD 018CTD/RosetteCTD-RO2017-03-06T18:46:00-22.00050-73.00050-4264
M135_196-1CTD 019CTD/RosetteCTD-RO2017-03-07T01:11:00-22.00000-71.99967-4332
M135_197-1CTD 020CTD/RosetteCTD-RO2017-03-07T04:50:00-22.00000-71.50000-5931
M135_198-1CTD 021CTD/RosetteCTD-RO2017-03-07T08:27:00-21.99967-70.99933-5268
M135_199-1CTD 022CTD/RosetteCTD-RO2017-03-07T10:44:00-22.00083-70.74917-3804
M135_200-1CTD/Rosette, ultra cleanCTD-UC2017-03-07T12:32:00-21.99967-70.51667-17382017-03-07T13:13:00-21.99967-70.51650-1735.1
M135_200-2CTD 023CTD/RosetteCTD-RO2017-03-07T13:59:00-21.99967-70.51650-1735
M135_201-1CTD 024CTD/RosetteCTD-RO2017-03-07T16:16:00-22.00000-70.29950-599
M135_202-1CTD 025CTD/RosetteCTD-RO2017-03-07T22:33:00-21.00017-70.41750-534
M135_203-1CTD/Rosette, ultra cleanCTD-UC2017-03-08T00:27:00-20.99950-70.68200-21152017-03-08T01:07:00-20.99917-70.68233-2121.1
M135_203-2CTD 026CTD/RosetteCTD-RO2017-03-08T01:57:00-20.99917-70.68267-2123
M135_204-1CTD 027CTD/RosetteCTD-RO2017-03-08T04:02:00-20.99967-70.83333-3177
M135_205-1CTD/Rosette, ultra cleanCTD-UC2017-03-08T05:32:00-21.00017-71.00050-45142017-03-08T06:13:00-21.00017-71.00083-4518.3
M135_205-2CTD 028CTD/RosetteCTD-RO2017-03-08T06:40:00-21.00017-71.00083-4516
M135_206-1CTD 029CTD/RosetteCTD-RO2017-03-08T10:20:00-21.00000-71.49917-5067
M135_207-1CTD/Rosette, ultra cleanCTD-UC2017-03-08T13:40:00-20.99967-71.99983-43222017-03-08T14:21:00-20.99950-72.00000-4322.7
M135_207-2CTD 030CTD/RosetteCTD-RO2017-03-08T14:49:00-20.99950-72.00017-4322
M135_208-1CTD/Rosette, ultra cleanCTD-UC2017-03-08T20:42:00-21.00000-73.00033-46602017-03-08T21:22:00-21.00000-73.00100-4663.4
M135_208-2CTD 031CTD/RosetteCTD-RO2017-03-08T21:50:00-21.00000-73.00117-4674
M135_209-1CTD 032CTD/RosetteCTD-RO2017-03-09T03:46:00-20.99967-73.99950-4653
M135_209-2CTD/Rosette, ultra cleanCTD-UC2017-03-09T04:25:00-20.99983-73.99967-4653
M135_209-3CTD 033CTD/RosetteCTD-RO2017-03-09T05:09:00-20.99967-73.99983-4653
M135_210-1CTD 034CTD/RosetteCTD-RO2017-03-09T12:42:00-20.00000-74.00000-4740
M135_211-1CTD 035CTD/RosetteCTD-RO2017-03-09T20:22:00-20.00033-72.99950-4560
M135_212-1CTD 036CTD/RosetteCTD-RO2017-03-10T02:58:00-20.00033-72.00183-4048
M135_213-1CTD 037CTD/RosetteCTD-RO2017-03-10T06:45:00-20.00000-71.50017-6583
M135_214-1CTD 038CTD/RosetteCTD-RO2017-03-10T10:28:00-19.99933-71.00000-2989
M135_215-1CTD/Rosette, ultra cleanCTD-UC2017-03-10T12:31:00-20.00017-70.75100-12662017-03-10T13:12:00-19.99983-70.75150-1264.2
M135_215-2CTD 039CTD/RosetteCTD-RO2017-03-10T13:44:00-19.99983-70.75167-1263
M135_216-1CTD 040CTD/RosetteCTD-RO2017-03-10T16:15:00-19.99983-70.50000-1185
M135_217-1CTD 041CTD/RosetteCTD-RO2017-03-10T18:19:00-20.00250-70.29883-989
M135_218-1MultibeamMB2017-03-10T18:45:00-20.00383-70.30350-9932017-03-11T12:30:00-18.62983-70.62067-1171.9
M135_219-1CTD 042CTD/RosetteCTD-RO2017-03-11T14:54:00-18.78917-70.85650-1413
M135_219-2MultiCorerMUC2017-03-11T15:31:00-18.78917-70.85650-14132017-03-11T16:28:00-18.78983-70.85650-1413.5
M135_219-3Gravity corerGC2017-03-11T16:51:00-18.78983-70.85650-14132017-03-11T17:47:00-18.78983-70.85650-1414.1
M135_220-1CTD 043CTD/RosetteCTD-RO2017-03-11T21:29:00-18.99983-70.41667-527
M135_221-1CTD 044CTD/RosetteCTD-RO2017-03-11T23:13:00-19.00000-70.58333-1206
M135_222-1CTD 045CTD/RosetteCTD-RO2017-03-12T01:17:00-18.99967-70.75017-1525
M135_223-1CTD 046CTD/RosetteCTD-RO2017-03-12T03:34:00-18.99967-71.00017-1752
M135_223-2CTD/Rosette, ultra cleanCTD-UC2017-03-12T03:46:00-18.99950-71.00017-17502017-03-12T04:25:00-18.99950-71.00083-1770.6
M135_223-3CTD 047CTD/RosetteCTD-RO2017-03-12T05:03:00-18.99950-71.00083-1770
M135_224-1CTD 048CTD/RosetteCTD-RO2017-03-12T08:58:00-19.00000-71.49983-3366
M135_225-1CTD 049CTD/RosetteCTD-RO2017-03-12T12:39:00-18.99950-71.99983-6764
M135_226-1CTD 050CTD/RosetteCTD-RO2017-03-12T18:58:00-18.99967-73.00167-4324
M135_227-1CTD/Rosette, ultra cleanCTD-UC2017-03-13T00:54:00-18.99933-74.00000-46982017-03-13T01:47:00-18.99850-74.00150-4696.9
M135_227-2CTD 051CTD/RosetteCTD-RO2017-03-13T02:15:00-18.99850-74.00167-4696
M135_228-1CTD 052CTD/RosetteCTD-RO2017-03-13T08:41:00-18.99983-75.00000-4851
M135_229-1CTD 053CTD/RosetteCTD-RO2017-03-13T15:14:00-18.99983-76.00017-4800
M135_230-1CTD 054CTD/RosetteCTD-RO2017-03-13T21:45:00-18.99950-77.00067-4454
M135_231-1CTD 055CTD/RosetteCTD-RO2017-03-14T04:04:00-18.99933-78.00050-4363
M135_232-1CTD 056CTD/RosetteCTD-RO2017-03-14T10:56:00-19.00000-79.00017-3660
M135_233-1CTD 057CTD/RosetteCTD-RO2017-03-14T17:18:00-19.00050-80.00150-3410
M135_234-1CTD/Rosette, ultra cleanCTD-UC2017-03-14T23:22:00-19.00000-81.00000-41272017-03-15T00:10:00-19.00017-81.00117-4126.1
M135_234-2CTD 058CTD/RosetteCTD-RO2017-03-15T00:39:00-19.00017-81.00083-4122
M135_235-1CTD 059CTD/RosetteCTD-RO2017-03-15T07:37:00-18.00000-81.00000-4426
M135_236-1CTD 060CTD/RosetteCTD-RO2017-03-15T14:36:00-18.00083-80.00167-3750
M135_236-2Micro structure probeMSS2017-03-15T15:54:00-17.99817-80.00833-37822017-03-15T16:06:00-18.00000-80.00450-3775.6
M135_236-3Micro structure probeMSS2017-03-15T16:31:00-18.00033-79.98750-36852017-03-15T17:29:00-17.99483-79.96817-3631.8
M135_237-1CTD/Rosette, ultra cleanCTD-UC2017-03-15T23:50:00-17.99950-79.00017-29182017-03-16T00:39:00-17.98983-79.01967-2929
M135_237-2CTD 061CTD/RosetteCTD-RO2017-03-16T01:11:00-17.98033-79.02850-2934
M135_238-1CTD 062CTD/RosetteCTD-RO2017-03-16T08:24:00-17.99967-78.00000-4166
M135_239-1CTD 063CTD/RosetteCTD-RO2017-03-16T15:02:00-18.00033-77.00100-4189
M135_240-1CTD/Rosette, ultra cleanCTD-UC2017-03-16T21:36:00-18.00050-76.00100-44262017-03-16T22:19:00-17.99850-76.01517-4465.1
M135_240-2CTD 064CTD/RosetteCTD-RO2017-03-16T23:49:00-17.99533-76.01483-4471
M135_241-1CTD 065CTD/RosetteCTD-RO2017-03-17T07:44:00-17.99383-75.00250-4449
M135_242-1CTD 066CTD/RosetteCTD-RO2017-03-17T14:34:00-17.99800-73.99833-4344
M135_243-1CTD 067CTD/RosetteCTD-RO2017-03-17T21:27:00-18.00100-73.00150-6274
M135_244-1CTD 068CTD/RosetteCTD-RO2017-03-18T01:21:00-17.99850-72.49833-4305
M135_245-1CTD/Rosette, ultra cleanCTD-UC2017-03-18T05:56:00-18.00017-71.91650-1946
M135_245-2CTD 069CTD/RosetteCTD-RO2017-03-18T07:12:00-18.00100-71.91750-2002
M135_246-1CTD 070CTD/RosetteCTD-RO2017-03-18T09:40:00-17.88583-71.71617-791
M135_247-1CTD 071CTD/RosetteCTD-RO2017-03-18T11:52:00-17.75033-71.51700-560
M135_247-2Micro structure probeMSS2017-03-18T12:15:00-17.75333-71.51533-5602017-03-18T13:28:00-17.77433-71.51500-583.3
M135_248-1MultibeamMB2017-03-19T01:24:00-17.52783-71.61100-5202017-03-19T21:00:00-17.48383-71.72083-509.4
M135_249-1CTD 072CTD/RosetteCTD-RO2017-03-19T21:21:00-17.48450-71.71783-464
M135_249-2MultiCorerMUC2017-03-19T21:40:00-17.48417-71.71817-5022017-03-19T22:02:00-17.48417-71.71817-511.3
M135_249-3Gravity corerGC2017-03-19T22:28:00-17.48417-71.71817-4642017-03-19T22:52:00-17.48417-71.71817-464
M135_249-4Gravity corerGC2017-03-19T23:14:00-17.48417-71.71817-4652017-03-19T23:41:00-17.48417-71.71817-464.7
M135_249-5Micro structure probeMSS2017-03-19T23:52:00-17.48467-71.71850-5102017-03-20T01:29:00-17.50783-71.72833-549.7
M135_250-1CTD/Rosette, ultra cleanCTD-UC2017-03-20T02:05:00-17.48317-71.68383-4692017-03-20T02:28:00-17.48333-71.68367-471.5
M135_250-2MultiCorerMUC2017-03-20T02:37:00-17.48283-71.68367-6312017-03-20T03:00:00-17.48283-71.68350-506.7
M135_250-3Gravity corerGC2017-03-20T03:25:00-17.48283-71.68350-5082017-03-20T03:49:00-17.48267-71.68350-506.5
M135_251-1MultibeamMB2017-03-20T04:13:00-17.48983-71.68817-4792017-03-20T12:41:00-17.35800-71.93583-289.4
M135_252-1CTD 073CTD/RosetteCTD-RO2017-03-20T14:10:00-17.40983-71.74000-229
M135_252-2MultiCorerMUC2017-03-20T14:20:00-17.40983-71.74017-2312017-03-20T14:37:00-17.41000-71.74033-228.9
M135_252-3Gravity corerGC2017-03-20T15:02:00-17.41000-71.74033-2302017-03-20T15:19:00-17.41000-71.74017-227.6
M135_252-4Micro structure probeMSS2017-03-20T15:36:00-17.41033-71.74033-2292017-03-20T18:08:00-17.42983-71.73167-325.5
M135_253-1MultibeamMB2017-03-20T18:52:00-17.41717-71.72667-3062017-03-20T20:36:00-17.43600-71.73050-341.3
M135_254-1CTD/Rosette, ultra cleanCTD-UC2017-03-20T21:01:00-17.42067-71.76900-1902017-03-20T21:16:00-17.42083-71.76883-191.7
M135_254-2MultiCorerMUC2017-03-20T21:24:00-17.42050-71.76900-1932017-03-20T21:37:00-17.42050-71.76900-192
M135_254-3Gravity corerGC2017-03-20T22:03:00-17.42050-71.76900-1972017-03-20T22:17:00-17.42050-71.76900-219.2
M135_254-4Micro structure probeMSS2017-03-20T22:24:00-17.42083-71.76933-1922017-03-21T00:03:00-17.40467-71.76500-157.8
M135_255-1CTD 074CTD/RosetteCTD-RO2017-03-21T01:53:00-17.30317-72.00517-415
M135_255-2Micro structure probeMSS2017-03-21T02:13:00-17.30433-72.00483-4402017-03-21T03:26:00-17.32900-72.01833-569.2
M135_256-1CTD 075CTD/RosetteCTD-RO2017-03-21T05:48:00-17.05050-72.20017-547
M135_256-2Micro structure probeMSS2017-03-21T06:12:00-17.05117-72.19883-5302017-03-21T07:25:00-17.04833-72.17817-473.4
M135_257-1CTD 076CTD/RosetteCTD-RO2017-03-21T09:39:00-16.86683-72.43300-749
M135_257-2Micro structure probeMSS2017-03-21T10:03:00-16.86617-72.43350-7832017-03-21T11:18:00-16.84883-72.42217-445.5
M135_258-1CTD 077CTD/RosetteCTD-RO2017-03-21T12:55:00-16.83300-72.66650-119
M135_258-2Micro structure probeMSS2017-03-21T13:09:00-16.83367-72.66683-1192017-03-21T13:55:00-16.83900-72.67017-120.1
M135_259-1CTD 078CTD/RosetteCTD-RO2017-03-21T16:15:00-16.99967-72.95267-1728
M135_259-2CTD/Rosette, ultra cleanCTD-UC2017-03-21T16:30:00-16.99967-72.95267-17302017-03-21T17:36:00-16.99933-72.95383-1733.6
M135_259-3CTD 079CTD/RosetteCTD-RO2017-03-21T18:20:00-16.99933-72.95417-1737
M135_260-1CTD 080CTD/RosetteCTD-RO2017-03-21T22:23:00-17.00267-73.49917-4063
M135_261-1CTD/Rosette, ultra cleanCTD-UC2017-03-22T01:42:00-17.00000-74.00000-8892017-03-22T02:22:00-17.00067-74.00133-1139.2
M135_261-2CTD 081CTD/RosetteCTD-RO2017-03-22T02:52:00-17.00050-74.00150-1338
M135_262-1CTD 082CTD/RosetteCTD-RO2017-03-22T09:14:00-17.00017-75.00033-4612
M135_263-1CTD 083CTD/RosetteCTD-RO2017-03-22T15:40:00-16.99933-76.00000-4274
M135_264-1CTD/Rosette, ultra cleanCTD-UC2017-03-22T21:43:00-16.99950-77.00017-34292017-03-22T22:22:00-16.99983-76.99917-3428.2
M135_264-2CTD 084CTD/RosetteCTD-RO2017-03-22T22:51:00-16.99967-76.99933-3427
M135_265-1CTD 085CTD/RosetteCTD-RO2017-03-23T05:18:00-16.99917-78.00067-2739
M135_266-1CTD/Rosette, ultra cleanCTD-UC2017-03-23T11:21:00-17.00033-78.99983-40372017-03-23T12:02:00-17.00017-79.00000-4037.1
M135_266-2CTD 086CTD/RosetteCTD-RO2017-03-23T12:32:00-17.00017-79.00000-4039
M135_267-1CTD 087CTD/RosetteCTD-RO2017-03-23T18:56:00-16.99967-80.00117-4480
M135_268-1CTD 088CTD/RosetteCTD-RO2017-03-24T01:10:00-16.99917-81.00183-4494
M135_269-1CTD/Rosette, ultra cleanCTD-UC2017-03-24T07:12:00-17.00017-82.00150-45922017-03-24T07:54:00-16.99950-82.00550-4579.8
M135_269-2CTD 089CTD/RosetteCTD-RO2017-03-24T08:20:00-16.99850-82.00800-4581
M135_270-1CTD 090CTD/RosetteCTD-RO2017-03-24T14:34:00-16.99883-83.00133-4542
M135_271-1CTD/Rosette, ultra cleanCTD-UC2017-03-24T20:42:00-17.00017-84.00150-48062017-03-24T21:19:00-17.00017-84.00233-4803.1
M135_271-2CTD 091CTD/RosetteCTD-RO2017-03-24T21:49:00-17.00050-84.00200-4805
M135_272-1CTD 092CTD/RosetteCTD-RO2017-03-25T04:05:00-17.00050-85.00000-4661
M135_273-1CTD 093CTD/RosetteCTD-RO2017-03-25T10:14:00-16.99983-86.00000-4473
M135_273-2CTD/Rosette, ultra cleanCTD-UC2017-03-25T10:35:00-17.00000-85.99967-44632017-03-25T11:14:00-16.99967-86.00017-4462.2
M135_273-3CTD 094CTD/RosetteCTD-RO2017-03-25T12:39:00-16.99983-86.00000-4463
M135_274-1CTD 095CTD/RosetteCTD-RO2017-03-26T20:43:00-16.00050-81.00000-4519
M135_275-1CTD/Rosette, ultra cleanCTD-UC2017-03-27T03:32:00-15.99983-80.00183-47282017-03-27T04:15:00-15.99983-80.00333-4735.3
M135_275-2CTD 096CTD/RosetteCTD-RO2017-03-27T05:50:00-15.99983-80.00350-4763
M135_276-1CTD 097CTD/RosetteCTD-RO2017-03-27T14:14:00-15.99983-79.00117-4365
M135_277-1CTD/Rosette, ultra cleanCTD-UC2017-03-27T21:00:00-16.00000-77.99983-34252017-03-27T21:39:00-16.00000-77.99983-3421.9
M135_277-2CTD 098CTD/RosetteCTD-RO2017-03-27T22:07:00-15.99950-77.99917-3428
M135_278-1CTD 099CTD/RosetteCTD-RO2017-03-28T05:19:00-16.00083-77.00167-2365
M135_279-1CTD/Rosette, ultra cleanCTD-UC2017-03-28T12:08:00-16.00050-76.00083-37252017-03-28T12:48:00-16.00033-76.00467-3719.3
M135_279-2CTD 100CTD/RosetteCTD-RO2017-03-28T13:20:00-15.99983-76.00600-3717
M135_280-1CTD 101CTD/RosetteCTD-RO2017-03-28T20:27:00-16.00050-75.00117-2876
M135_281-1CTD/Rosette, ultra cleanCTD-UC2017-03-28T22:44:00-16.00050-74.75017-21212017-03-29T00:03:00-16.00050-74.75067-2121.1
M135_281-2CTD 102CTD/RosetteCTD-RO2017-03-29T00:50:00-16.00050-74.75067-2126
M135_282-1MultibeamMB2017-03-29T01:43:00-16.00133-74.74933-21272017-03-29T06:47:00-16.08500-74.56750-1851.9Begin Profile
M135_282-2CTD, underwayCTD-UW2017-03-29T01:48:00-15.99233-74.74533-20362017-03-29T06:46:00-16.08317-74.56700-1831.1
M135_283-1CTD 103CTD/RosetteCTD-RO2017-03-29T07:50:00-15.98333-74.56683-816
M135_284-1Micro structure probeMSS2017-03-29T08:19:00-15.98150-74.56717-7862017-03-29T09:39:00-15.95800-74.57050-1077.9
M135_285-1Micro structure probeMSS2017-03-29T10:21:00-15.86567-74.58350-6652017-03-29T11:40:00-15.84483-74.59050-455.5
M135_286-1Micro structure probeMSS2017-03-29T12:01:00-15.81633-74.60000-2512017-03-29T12:51:00-15.80100-74.60050-319.3
M135_287-1CTD 104CTD/RosetteCTD-RO2017-03-29T13:26:00-15.76583-74.60033-125
M135_287-2Micro structure probeMSS2017-03-29T13:43:00-15.76583-74.60033-1252017-03-29T14:09:00-15.75933-74.59950-122.2
M135_288-1CTD/Rosette, ultra cleanCTD-UC2017-03-29T18:49:00-15.41717-75.25133-2702017-03-29T19:03:00-15.41650-75.25450-296.6
M135_288-2CTD 105CTD/RosetteCTD-RO2017-03-29T19:19:00-15.41667-75.25483-296
M135_288-3Micro structure probeMSS2017-03-29T19:38:00-15.41417-75.25600-2772017-03-29T20:30:00-15.39417-75.25800-166.7
M135_289-1CTD 106CTD/RosetteCTD-RO2017-03-30T00:06:00-15.00000-75.75017-211
M135_289-2Micro structure probeMSS2017-03-30T00:21:00-15.00050-75.75000-1792017-03-30T00:58:00-15.00617-75.74883-184.5
M135_290-1CTD 107CTD/RosetteCTD-RO2017-03-30T03:25:00-15.00117-76.08933-2009
M135_290-2CTD/Rosette, ultra cleanCTD-UC2017-03-30T03:41:00-15.00100-76.08983-20052017-03-30T05:00:00-15.00017-76.09600-2037.2
M135_290-3CTD 108CTD/RosetteCTD-RO2017-03-30T05:43:00-15.00017-76.09617-2035
M135_291-1CTD 109CTD/RosetteCTD-RO2017-03-30T09:01:00-15.00067-76.50200-4425
M135_292-1CTD 110CTD/RosetteCTD-RO2017-03-30T12:39:00-15.00000-76.99967-3786
M135_293-1CTD/Rosette, ultra cleanCTD-UC2017-03-30T18:53:00-14.99983-77.99983-41482017-03-30T19:32:00-14.99967-78.00017-4151.8
M135_293-2CTD 111CTD/RosetteCTD-RO2017-03-30T20:00:00-14.99983-77.99867-4148
M135_294-1CTD 112CTD/RosetteCTD-RO2017-03-31T00:00:00-15.00000-78.49983-4176
M135_295-1CTD 113CTD/RosetteCTD-RO2017-03-31T03:46:00-15.00083-78.99917-4185
M135_296-1CTD 114CTD/RosetteCTD-RO2017-03-31T10:36:00-15.00000-79.99967-4669
M135_297-1CTD 115CTD/RosetteCTD-RO2017-03-31T16:49:00-14.99950-81.00067-4647
M135_297-2CTD/Rosette, ultra cleanCTD-UC2017-03-31T17:02:00-14.99950-81.00067-46412017-03-31T17:42:00-14.99933-81.00467-4637.4
M135_297-3CTD 116CTD/RosetteCTD-RO2017-03-31T18:10:00-14.99917-81.00617-4646
M135_298-1CTD 117CTD/RosetteCTD-RO2017-04-01T01:10:00-14.00000-81.00067-4800
M135_299-1CTD/Rosette, ultra cleanCTD-UC2017-04-01T07:53:00-14.00017-80.00200-46512017-04-01T08:33:00-13.99983-80.00367-4640.2
M135_299-2CTD 118CTD/RosetteCTD-RO2017-04-01T09:04:00-14.00000-80.00433-4625
M135_300-1CTD 119CTD/RosetteCTD-RO2017-04-01T16:24:00-14.00167-79.00233-4474
M135_301-1CTD/Rosette, ultra cleanCTD-UC2017-04-01T23:58:00-13.99983-78.00033-46382017-04-02T00:41:00-13.99983-78.00050-4635.9
M135_301-2CTD 120CTD/RosetteCTD-RO2017-04-02T01:12:00-13.99983-78.00050-5493
M135_302-1CTD 121CTD/RosetteCTD-RO2017-04-02T05:33:00-13.99983-77.50017-5110
M135_302-2CTD, underwayCTD-UW2017-04-02T06:12:00-13.98867-77.47467-48452017-04-02T09:22:00-13.79383-77.05067-2017.5
M135_303-1CTD/Rosette, ultra cleanCTD-UC2017-04-02T09:46:00-13.79933-77.05000-20222017-04-02T11:04:00-13.79950-77.05017-2020.2
M135_303-2CTD 122CTD/RosetteCTD-RO2017-04-02T11:49:00-13.79950-77.05017-2023
M135_304-1CTD, underwayCTD-UW2017-04-02T12:42:00-13.79317-77.04233-19582017-04-02T16:07:00-13.66083-76.75717-297.8
M135_305-1CTD 123CTD/RosetteCTD-RO2017-04-02T16:29:00-13.66617-76.75033-289
M135_306-1CTD, underwayCTD-UW2017-04-02T16:47:00-13.66933-76.75083-2952017-04-02T19:29:00-13.68617-76.48650-124.9
M135_307-1CTD 124CTD/RosetteCTD-RO2017-04-03T00:36:00-14.03317-76.53367-259
M135_308-1CTD/Rosette, ultra cleanCTD-UC2017-04-03T01:40:00-14.08300-76.63383-6002017-04-03T02:09:00-14.08367-76.63633-650.9
M135_309-1GliderGLD2017-04-03T14:30:00-14.02317-76.88717-20982017-04-03T14:58:00-14.02433-76.89017-2118.6Deployment
M135_310-1CTD 125CTD/RosetteCTD-RO2017-04-03T15:46:00-14.04183-76.88667-2111
M135_310-2GliderGLD2017-04-03T16:12:00-14.04167-76.88533-21062017-04-03T16:39:00-14.04350-76.89000-2130.6Deployment
M135_311-1CTD 126CTD/RosetteCTD-RO2017-04-04T00:17:00-13.00033-77.00000-417
M135_312-1CTD 127CTD/RosetteCTD-RO2017-04-04T02:30:00-12.99933-77.24933-1239
M135_313-1CTD 128CTD/RosetteCTD-RO2017-04-04T05:21:00-12.99967-77.61717-2027
M135_313-2CTD/Rosette, ultra cleanCTD-UC2017-04-04T05:34:00-12.99967-77.61683-20252017-04-04T06:48:00-13.00000-77.61683-2026.5
M135_313-3CTD 129CTD/RosetteCTD-RO2017-04-04T07:26:00-13.00000-77.61650-2028
M135_314-1CTD 130CTD/RosetteCTD-RO2017-04-04T10:32:00-13.00000-77.99950-3531
M135_315-1CTD 131CTD/RosetteCTD-RO2017-04-04T17:05:00-12.99967-79.00067-4763
M135_315-2CTD/Rosette, ultra cleanCTD-UC2017-04-04T17:32:00-12.99967-79.00083-47622017-04-04T18:10:00-12.99983-79.00267-4759.5
M135_316-1CTD 132CTD/RosetteCTD-RO2017-04-05T00:18:00-12.99967-79.99983-4729
M135_317-1CTD 133CTD/RosetteCTD-RO2017-04-05T06:49:00-12.99950-81.00133-4683
M135_317-2CTD/Rosette, ultra cleanCTD-UC2017-04-05T06:58:00-12.99933-81.00083-46832017-04-05T07:35:00-12.99933-81.00133-4682.8
M135_317-3CTD 134CTD/RosetteCTD-RO2017-04-05T08:02:00-12.99950-81.00183-4683
M135_318-1CTD 135CTD/RosetteCTD-RO2017-04-05T14:51:00-12.00017-81.00200-4518
M135_319-1CTD 136CTD/RosetteCTD-RO2017-04-05T22:32:00-11.99983-80.001170
M135_320-1CTD/Rosette, ultra cleanCTD-UC2017-04-06T04:13:00-11.99967-79.20033-55412017-04-06T04:52:00-11.99950-79.20083-5538.6
M135_320-2CTD 137CTD/RosetteCTD-RO2017-04-06T05:20:00-11.99967-79.19967-5542
M135_321-1CTD 138CTD/RosetteCTD-RO2017-04-06T12:42:00-11.00017-78.76750-2105
M135_321-2MultibeamMB2017-04-06T13:28:00-11.00033-78.76783-21052017-04-06T17:45:00-10.65567-78.14567-160.6Begin Profile
M135_321-3CTD, underwayCTD-UW2017-04-06T13:46:00-10.98750-78.74333-20102017-04-06T17:43:00-10.65517-78.14867-163.7
M135_322-1CTD 139CTD/RosetteCTD-RO2017-04-06T18:06:00-10.67083-78.14550-169
M135_323-1CTD 140CTD/RosetteCTD-RO2017-04-06T19:05:00-10.71667-78.23383-252
M135_322-2MultibeamMB2017-04-06T19:16:00-10.71667-78.23350-2522017-04-07T03:28:00-12.04333-78.16700-2063.2Begin Profile
M135_322-3CTD, underwayCTD-UW2017-04-06T19:22:00-10.72650-78.23317-2552017-04-06T22:35:00-11.25950-78.20750-487.4
M135_324-1CTD 141CTD/RosetteCTD-RO2017-04-07T04:19:00-12.05000-78.16650-2077
M135_324-2CTD/Rosette, ultra cleanCTD-UC2017-04-07T05:04:00-12.05000-78.16650-20762017-04-07T06:23:00-12.05050-78.16717-2077.3
M135_325-1CTD 142CTD/RosetteCTD-RO2017-04-07T11:26:00-12.36650-77.43350-737
M135_326-1Micro structure probeMSS2017-04-07T12:26:00-12.44950-77.50000-4592017-04-07T13:53:00-12.46217-77.50850-471.9
M135_327-1Micro structure probeMSS2017-04-07T14:42:00-12.41650-77.43400-3002017-04-07T15:50:00-12.43067-77.43833-310.1
M135_328-1CTD/Rosette, ultra cleanCTD-UC2017-04-07T16:31:00-12.38267-77.39967-2342017-04-07T16:43:00-12.38267-77.39967-234.6
M135_328-2Micro structure probeMSS2017-04-07T16:56:00-12.38300-77.39967-2352017-04-07T18:03:00-12.40083-77.40467-258
M135_329-1Micro structure probeMSS2017-04-07T18:38:00-12.35067-77.36533-1922017-04-07T19:38:00-12.36683-77.36917-204.9
M135_330-1Micro structure probeMSS2017-04-07T20:18:00-12.31550-77.30100-1492017-04-07T21:15:00-12.33200-77.30083-157.1
M135_331-1Micro structure probeMSS2017-04-07T21:52:00-12.28467-77.25017-1302017-04-07T22:47:00-12.30100-77.25017-133.2
M135_332-1Micro structure probeMSS2017-04-07T23:24:00-12.25100-77.21683-1092017-04-08T00:18:00-12.26967-77.21950-118.3
M135_333-1Micro structure probeMSS2017-04-08T01:00:00-12.21800-77.18367-732017-04-08T01:46:00-12.23517-77.18967-83.7
M135_334-1Acoustic Doppler Current ProfilerADCP2017-04-08T05:08:00-12.56933-77.63400-10002017-04-08T10:46:00-12.22050-77.18833-76.7